Home About Us Products Digital Catalogs Dealer Locator Links Request Info Contact Us Site map
  Photo Gallery

  Product Colors

  Product Shapes

  Cost Comparison

  R-Values

  ASTM Reports

  Graffiti Removal

  Fire Ratings

  Specifications

  Cleaning

  FAQ
Fire Ratings
TRENDSTONEŽ Fire Ratings

Thickness
 
Minimum

Thickness
Solid

Volume
Equivalent

Solid Thickness
Fire

Rating
Weight Per

Unit Light
Nominal
Actual
Type
Shell

Inches
Web

Inches
Percent
Inches
Hours
Weight

Pounds
4"
3 5/8"
hollow
1.00
1.00
72
2.61
1
23
6"
5 5/8"
hollow
1.12
1.00
61
3.43
1
29
semi-solid
1.75
1.00
75
4.25
2
40
8"
7 5/8"
hollow
1.25
1.00
53
4.04
2
40
semi-solid
2.25
1.25
80
6.10
4
43
10"
9 5/8"
hollow
1.50
1.12
54
5.18
3
51
12"
11 5/8"
hollow
1.50
1.25
52
6.05
4
54

The fire ratings shown are based on data published by the National Concrete Masonry Association in NCMA TEK 7-1 and the National Bureau of Standards Report BMS 92. Table 26.

The above fire resistance ratings are based on plain walls; and application of gypsum plaster (1/2") will add 1/2 hour to ratings. Other aggregates not included above may have slightly different fire ratings.

The masonry industry and building codes have adopted a standard method for computing fire resistance ratings of concrete block based on the aggregate used and the amount of solid content of the blocks used.

Data based on units 7 5/8" high by 15 5/8" long

Site by Clearimaging.com